Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
guides:esxi_host_bootstrap [2019/05/14 02:05] sjames5 [5. NICs] update wording |
guides:esxi_host_bootstrap [2021/10/15 21:37] sjames5 Update DNS server addresses |
||
---|---|---|---|
Line 29: | Line 29: | ||
* Enter the correct information. See [this page](/cdr/networks/management) for detailed information | * Enter the correct information. See [this page](/cdr/networks/management) for detailed information | ||
* IPv4 Address: Check IP Ranges | * IPv4 Address: Check IP Ranges | ||
- | * Subnet Mask: 255.255.255.192 | + | * Subnet Mask: 255.255.255.128 |
- | * Default Gateway: 128.205.44.129 | + | * Default Gateway: 128.205.44.254 |
* Go to "IPv6 Configuration" | * Go to "IPv6 Configuration" | ||
* Disable it | * Disable it | ||
* Go to "DNS Configuration" | * Go to "DNS Configuration" | ||
* Select "Use the following DNS Server" | * Select "Use the following DNS Server" | ||
- | * Primary DNS Server: 128.205.1.2 | + | * Primary DNS Server: 128.205.1.100 |
- | * Secondary DNS Server: 128.205.32.8 | + | * Secondary DNS Server: 128.205.1.101 |
* Hostname: cdr-vhostX | * Hostname: cdr-vhostX | ||
* Do **NOT** include `.cse.buffalo.edu` | * Do **NOT** include `.cse.buffalo.edu` | ||
Line 52: | Line 52: | ||
* Username: root | * Username: root | ||
* Password: <the password you setup> | * Password: <the password you setup> | ||
- | * Enable Lockdown Mode | ||
* Press continue through everything else | * Press continue through everything else | ||
+ | * Enable Lockdown Mode | ||
+ | * Configuration -> Security Profile -> Lockdown Mode (Normal, not Strict) | ||
+ | |||
After a bit, the host should show up in the cluster you added it to. Woot! Now, setup the reset of the network connections, and datastore connections | After a bit, the host should show up in the cluster you added it to. Woot! Now, setup the reset of the network connections, and datastore connections | ||
Line 65: | Line 67: | ||
* VMkernel Network Adapter | * VMkernel Network Adapter | ||
* New standard switch | * New standard switch | ||
+ | * Select appropriate adapter | ||
* Use the network label `direct-io` | * Use the network label `direct-io` | ||
* Use [static IPv4 settings](/cdr/networks/direct-io) | * Use [static IPv4 settings](/cdr/networks/direct-io) | ||
Line 87: | Line 90: | ||
* 10.0.0.155 | * 10.0.0.155 | ||
* 10.0.0.160 | * 10.0.0.160 | ||
+ | * Rescan the ISCSI Adapter | ||
===== 8. Host datastore ===== | ===== 8. Host datastore ===== |