Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
guides:esxi_host_bootstrap [2019/05/14 01:42] sjames5 Add section for host's datastore |
guides:esxi_host_bootstrap [2021/10/15 21:37] (current) sjames5 Update DNS server addresses |
||
---|---|---|---|
Line 29: | Line 29: | ||
* Enter the correct information. See [this page](/cdr/networks/management) for detailed information | * Enter the correct information. See [this page](/cdr/networks/management) for detailed information | ||
* IPv4 Address: Check IP Ranges | * IPv4 Address: Check IP Ranges | ||
- | * Subnet Mask: 255.255.255.192 | + | * Subnet Mask: 255.255.255.128 |
- | * Default Gateway: 128.205.44.129 | + | * Default Gateway: 128.205.44.254 |
* Go to "IPv6 Configuration" | * Go to "IPv6 Configuration" | ||
* Disable it | * Disable it | ||
* Go to "DNS Configuration" | * Go to "DNS Configuration" | ||
* Select "Use the following DNS Server" | * Select "Use the following DNS Server" | ||
- | * Primary DNS Server: 128.205.1.2 | + | * Primary DNS Server: 128.205.1.100 |
- | * Secondary DNS Server: 128.205.32.8 | + | * Secondary DNS Server: 128.205.1.101 |
* Hostname: cdr-vhostX | * Hostname: cdr-vhostX | ||
* Do **NOT** include `.cse.buffalo.edu` | * Do **NOT** include `.cse.buffalo.edu` | ||
Line 52: | Line 52: | ||
* Username: root | * Username: root | ||
* Password: <the password you setup> | * Password: <the password you setup> | ||
- | * Enable Lockdown Mode | ||
* Press continue through everything else | * Press continue through everything else | ||
+ | * Enable Lockdown Mode | ||
+ | * Configuration -> Security Profile -> Lockdown Mode (Normal, not Strict) | ||
+ | |||
After a bit, the host should show up in the cluster you added it to. Woot! Now, setup the reset of the network connections, and datastore connections | After a bit, the host should show up in the cluster you added it to. Woot! Now, setup the reset of the network connections, and datastore connections | ||
===== 5. NICs ===== | ===== 5. NICs ===== | ||
- | * Modify the [Management Network](/cdr/networks/management) NIC | + | Host : `Configure` : `Networking` : `Virtual switches` |
+ | * Modify the [Management Network](/cdr/networks/management) switch | ||
* Change name to "DO NOT USE - CSE Management Network" from "VM Network" | * Change name to "DO NOT USE - CSE Management Network" from "VM Network" | ||
- | * Enable vMotion for the port on that switch | + | * Enable vMotion for the port on that switch (This is located below "VMkernel Ports" Menu. |
- | * Add a new NIC for [Direct IO](/cdr/networks/direct-io) | + | * Add a new NIC and vSwitch for [Direct IO](/cdr/networks/direct-io) |
* VMkernel Network Adapter | * VMkernel Network Adapter | ||
* New standard switch | * New standard switch | ||
+ | * Select appropriate adapter | ||
* Use the network label `direct-io` | * Use the network label `direct-io` | ||
* Use [static IPv4 settings](/cdr/networks/direct-io) | * Use [static IPv4 settings](/cdr/networks/direct-io) | ||
Line 69: | Line 73: | ||
* Use the existing switch created above | * Use the existing switch created above | ||
* Use the network label `io-net` | * Use the network label `io-net` | ||
+ | |||
+ | From the Networking section of vCenter (i.e. not for the specific host) | ||
* Add the host to [vDS](/misc/what_is_vds) (both [vds-core-nets](/cdr/networks/vds-core-nets) and [vds-team-nets](/cdr/networks/vds-team-nets)) | * Add the host to [vDS](/misc/what_is_vds) (both [vds-core-nets](/cdr/networks/vds-core-nets) and [vds-team-nets](/cdr/networks/vds-team-nets)) | ||
- | ===== 6. iSCSI ===== | + | ===== 6. NTP ===== |
+ | Host : `Configure` : `Time Configuration` | ||
+ | * Use Network Time Protocol | ||
+ | * NTP Servers: `tick.cse.buffalo.edu, tock.cse.buffalo.edu, ticktock.cse.buffalo.edu` | ||
+ | * Start NTP service | ||
+ | |||
+ | ===== 7. iSCSI ===== | ||
+ | Host : `Configure` : `Storage` : `Storage Adapters` | ||
* Add Software iSCSI Adapter | * Add Software iSCSI Adapter | ||
* Dynamic Discovery | * Dynamic Discovery | ||
Line 77: | Line 90: | ||
* 10.0.0.155 | * 10.0.0.155 | ||
* 10.0.0.160 | * 10.0.0.160 | ||
+ | * Rescan the ISCSI Adapter | ||
- | ===== 7. Host datastore ===== | + | ===== 8. Host datastore ===== |
At this point, you should already have the iSCSI servers connected. The host's own datastore is also connected. | At this point, you should already have the iSCSI servers connected. The host's own datastore is also connected. | ||
* Rename the host's datastore to `datastore-vhostX` | * Rename the host's datastore to `datastore-vhostX` | ||
* Move the datastore into the `Host Datastores` folder | * Move the datastore into the `Host Datastores` folder | ||
- | ===== 8. Bask in your Awesomeness ===== | + | ===== 9. Bask in your Awesomeness ===== |
{{:guides:gg.jpg?400|}} | {{:guides:gg.jpg?400|}} | ||